Home / Products / 14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U
14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U
Basic PDU

14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U

Quick Answer14-Outlet Swiss SEV 1011 Vertical Rack PDU, 220 V, 10 A per Outlet, 0U — an IDCPDU Basic PDU for data-centre and equipment-room racks.
  1. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  2. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  3. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  4. Master switch on the body — Field maintenance starts with one visible break, which is exactly what a lockout/tagout procedure asks for.
  5. Passive build, nothing to fail — No metering board and no switching relay inside — for a basic strip that means fewer parts that can take a rack down.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Vertical 0U strip for 19-inch server racks
  • 14 Swiss SEV 1011 (Type J) outlets, 10 A each
  • Master switch for one-touch isolation during service
  • The 505 mm mounting length suits 22U to 27U cabinets, wall boxes and network enclosures; the 120 × 45 mm extruded body keeps the rear cable path clear and the strip is fixed with the supplied M6 screws on ⁦465–505⁩ mm centres.
  • Outlets are fed from a single copper busbar with resistance-welded taps instead of daisy-chained leads, so the last outlet sees practically the same voltage as the first when all 14 are loaded.
  • Typical installations: Swiss and Liechtenstein IT rooms, branch offices and laboratory racks where IEC C13 is not the local socket standard.
  • Other socket combinations, cable lengths and plug types are built to drawing: layout within 30 minutes, quotation within 1 hour.

Frequently Asked Questions

Which racks does a 505 mm vertical strip fit?

It suits 19-inch racks with ⁦465–505⁩ mm rail centres — typically 22U to 27U cabinets, wall boxes and network enclosures. Measure the rail centres before ordering; longer strips are available to drawing.

Can the 14 outlets be split into two circuits?

Yes. The standard version is one feed with a master switch; for two feeds we build a dual-terminal version so each group of seven outlets sits on its own branch.

Is there overload protection inside the strip?

No breaker is fitted in the standard version — protection is expected upstream at the rack UPS or panel. If local code requires it, a 16 A hydraulic magnetic breaker can be added without changing the 120 × 45 mm body.

Which plugs go into these Swiss outlets?

Swiss SEV 1011 Type J plugs rated 10 A, which covers servers supplied with Swiss cords and C13-to-Type-J adapter cables.

How are the outlets wired internally?

All 14 sit on one copper busbar with welded taps rather than chained leads, so voltage at the last outlet stays within a few tenths of a volt of the first at full load.

How fast can a custom socket mix be delivered?

Layout drawing within 30 minutes of your requirement, quotation within 1 hour, and ⁦7–15⁩ working days for production after drawing approval.