| Rack standard | 19-inch EIA-310 |
| Installation | Vertical (0U) |
| Height | 1.5U body section (45 mm) |
| Mounting length | 1358 mm |
| Outlet configuration | 12× IEC C13 + 4× IEC C19 |
| Outlet rating | C13: 10 A; C19: 16 A |
| Input connection | Hard-wired terminal block, 5-wire |
| Input voltage | 110–250 V AC, 50/60 Hz |
| Max input current | 16 A (32 A version to order) |
| Rated power | 3.5 kW at 16 A; 7.0 kW at 32 A |
| Phase | Single-phase |
| Main breaker | 2× 1-pole hydraulic-magnetic breaker, 32 A |
| Surge protection | None |
| Metering | LCD, current / voltage / power / energy |
| Monitoring interface | TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485 |
| Outlet switching | Per-outlet remote on/off and metering |
| Housing | Cold-rolled steel, black powder coat |
| Operating temperature | -10–45 °C |
| Relative humidity | 0–90% RH, non-condensing |
| Included accessories | M6×16 screws, user manual |
| Certification | CE / EMC / RoHS; built under ISO 9001 |
| Customisation | Outlet count, cord length and plug type to drawing |
| Lead time | 7–15 working days after drawing approval |
Datasheet, manual and drawings for this product (PDF).
Our engineers reply within 24 hours on business days.
Tel: +86-574-63783045
Email: ricky@idcpdu.com
Tell us your requirements — our sales team will get back to you with a quotation.
A metered strip only reports current and power. This one also has a relay at every outlet, so the NOC can switch a single socket on or off remotely — the usual way to power-cycle a frozen server without sending an engineer to site.
Yes. Outlets are switched individually, so only the selected socket loses power. The other outlets keep running and stay on the same metering record.
The strip is built as two groups of eight outlets. Two 1-pole 32 A hydraulic-magnetic breakers give each group its own branch protection, so a fault in one group does not take the whole rack down and the remaining group still has a live feed.
Inrush from fifteen or sixteen switch-mode supplies at once can trip the upstream breaker. The start interval is adjustable from 1 to 250 seconds, so outlets come up one after another instead of as a single surge.
SNMP v1, v2 and v3, Modbus TCP, Modbus RTU over RS485, plus HTTP/HTTPS and SSH. It also accepts up to three slave strips on one master, so four strips appear as one device in the NMS.
Yes. Outlet count, C13 and C19 ratio, cord length and plug type are all built to drawing. We issue drawings within 30 minutes of your requirement and a quotation within one hour.