Home / Products / 16-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Main and Branch Breakers, 0U
16-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Main and Branch Breakers, 0U
Basic PDU

16-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Main and Branch Breakers, 0U

Quick Answer16-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Main and Branch Breakers, 0U — an IDCPDU Basic PDU for data-centre and equipment-room racks.
  1. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  2. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  3. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  4. Passive build, nothing to fail — No metering board and no switching relay inside — for a basic strip that means fewer parts that can take a rack down.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • 16 Chinese-standard sockets on a 0U vertical strip
  • 63 A input split across main and branch breakers
  • 1398 mm mounting length for 42U cabinets
  • The 125 × 62 mm body mounts in the rear rail channel of a 42U cabinet and leaves the side cable managers free. Sockets are the GB three-pin type with anti-drop latch, so plugs cannot work loose under vibration.
  • Power enters through an OT terminal junction box — no plug to be pulled out by accident — and is distributed from a tinned copper busbar. The main breaker isolates the whole strip, while branch breakers protect each group of outlets.
  • Used in Chinese data centres, telecom base stations and factory IT rooms where GB sockets, not IEC C13, are the installed standard.
  • Other outlet counts, branch groupings and cable lengths are made to drawing: layout within 30 minutes, quotation within 1 hour.

Frequently Asked Questions

Is 63 A the input rating or the outlet rating?

63 A is the maximum input current of the strip; each GB outlet is rated 10 A. The branch breakers split that 63 A across outlet groups so a single overloaded device trips its own branch rather than the whole strip.

Can this PDU be fed from a 32 A circuit?

Yes. The strip accepts any upstream protection up to 63 A; with a 32 A feed you simply keep the total load under 32 A and the main breaker acts as a backup isolator.

Do GB sockets hold plugs in mobile or vibrating racks?

Yes. Every outlet has an anti-drop latch, which is why this version is used in telecom base stations and factory floors where racks are subject to vibration.

Can I get the same strip with IEC C13 or C19 outlets?

Yes — the housing, busbar and breaker set are unchanged; we swap the outlet module. Mixed C13 and C19 layouts are also built to drawing.

How much rear space does the body take?

The body is 125 mm wide and 62 mm deep, so it fits the rear rail channel of a standard 42U cabinet while keeping side cable managers usable.

What is the lead time for 50 units?

Drawing confirmation within 1 hour, quotation within 1 hour, and ⁦10–20⁩ working days for 50 units depending on the socket mix.