Home / Products / 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U
20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U
Metered PDU

20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U

Quick Answer20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. 20 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  3. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  4. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Runs below zero — Tested from sub-zero ambient upward, so cold shelters and unheated halls are inside the envelope, not outside it.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Networked 0U meter strip for 20 C13/C19 outlets, 63 A input
  • TCP/IP and environmental sensor report load, temperature and humidity
  • 1358 mm mounting length fits 42U to 47U cabinets
  • The inlet takes a 63 A feed through an OT terminal junction box, which covers a full 42U cabinet of blade servers on one strip without a second drop. The network card serves a web page and SNMP, and the sensor port carries temperature and humidity so hot spots are caught before they trip a server. Branch protection is hydraulic magnetic, immune to the thermal drift that nuisance-trips MCBs in warm cabinets.

Frequently Asked Questions

What does the environmental sensor actually measure?

Temperature and humidity at the probe, with 1% humidity resolution, reported through the same network card as the electrical data. It lets you set a temperature threshold for the top of the rack, which is where recirculation shows up first.

Does a 63 A inlet mean each outlet can draw 63 A?

No. The 63 A is the strip inlet; outlets stay at their own rating, 10 A for C13 and 16 A for C19. The inlet rating sets how much total load one strip can carry — enough for a fully populated 42U cabinet on a single feed.

Which cabinets does the 1358 mm mounting length fit?

42U to 47U cabinets, where the rail centres fall near this length. Measure the rail centres before ordering: a strip that is too short cannot be bolted at both ends, and one that is too long will not clear the cabinet door.

Why hydraulic magnetic breakers instead of MCBs?

A thermal-magnetic MCB derates as the cabinet warms, so a circuit running near its rating trips on temperature rather than current. A hydraulic magnetic breaker responds to current only, which keeps the trip point stable from -10 °C to 45 °C.

How is the strip integrated with a DCIM or BMS?

Over SNMP v1/v2/v3 or Modbus TCP. Point the collector at the strip's IP address, enable the protocol in the web page, and current, power, energy, temperature and humidity appear as standard objects.

Can the outlet mix be adjusted for a specific cabinet layout?

Yes. The C13 to C19 split, cord length and plug type are built to drawing. Send the layout and we return a drawing within 30 minutes and a quotation within the hour.