| Rack standard | 19-inch EIA-310 |
| Installation | Vertical (0U) |
| Height | 1.5U body section (45 mm) |
| Mounting length | 1358 mm |
| Outlet configuration | 24× Brazilian NBR 14136, 12 per group |
| Outlet rating | 10 A per outlet (16 A version to order) |
| Input connection | Hard-wired terminal block, 5-wire |
| Input voltage | 220–250 V AC, 50/60 Hz |
| Max input current | 16 A (32 A version to order) |
| Rated power | 3.5 kW at 16 A; 7.0 kW at 32 A |
| Phase | Single-phase |
| Main breaker | 2× 1-pole hydraulic-magnetic breaker, 32 A |
| Surge protection | None |
| Metering | LCD, current / voltage / power / energy |
| Monitoring interface | TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485 |
| Outlet switching | Per-outlet remote on/off and metering |
| Cable entry | Top or bottom |
| Housing | Cold-rolled steel, black powder coat |
| Operating temperature | -10–45 °C |
| Relative humidity | 0–90% RH, non-condensing |
| Included accessories | M6×16 screws, user manual |
| Certification | CE / EMC / RoHS; built under ISO 9001 |
| Customisation | Outlet count, cord length and plug type to drawing |
| Lead time | 7–15 working days after drawing approval |
Datasheet, manual and drawings for this product (PDF).
Our engineers reply within 24 hours on business days.
Tel: +86-574-63783045
Email: ricky@idcpdu.com
Tell us your requirements — our sales team will get back to you with a quotation.
The strip itself is built for 220–250 V. Brazilian sites run 127 V and 220 V in the same building, so confirm the branch voltage before ordering: a 127 V feed needs a different internal build and cannot be converted on site.
NBR 14136 is used in 10 A and 20 A patterns. The 10 A outlet takes the thinner 10 A plug, while the 20 A pattern takes the wider 20 A plug. Tell us the mix when ordering so the right pattern is fitted in each position.
Because a Brazilian rack usually draws from two branch circuits. Two 32 A breakers give each group its own protection and let you feed the strip from two separate panel breakers, so one tripped branch does not silence the entire cabinet.
Both. Each outlet has its own relay, and groups can be defined in the web interface for a single command. In practice a NOC switches one outlet to reboot a server, and a group when a whole enclosure is taken down for maintenance.
Overall length is 1391 mm with a 1358 mm fixing hole spacing, which matches the standard mounting centres of a 42U cabinet. A 47U cabinet needs a longer body, which we build to drawing.
Yes. Outlet count, Brazilian or IEC positions, breaker rating, cord length and plug type are all built to drawing. Drawings within 30 minutes, quotation within one hour.