Home / Products / 600 kW GPU Cabinet CDU for GB200 / GB300
600 kW GPU Cabinet CDU for GB200 / GB300
CDU

600 kW GPU Cabinet CDU for GB200 / GB300

Quick Answer600 kW GPU Cabinet CDU for GB200 / GB300 — an IDCPDU CDU for liquid-cooled high-density racks.
  1. 600 kW in one cabinet, built around GPU racks — Sized for GB200/GB300-class trays, so the cooling unit matches the rack it stands beside instead of being a compromise both ways.
  2. Dew-point supervision — Condensation is the failure nobody sees coming; the control tracks dew point and acts before water forms on a cold plate.
  3. Rated for 24/7 duty — Continuous operation is the design case, not an overload condition — the loop is sized for heat that never stops.
  4. Load-following variable-speed pumps — Flow tracks the actual IT load instead of running at fixed speed, which is where a large part of the pump energy goes to waste.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • 600 kW liquid-to-liquid cabinet for GB200 and GB300 racks.
  • One cabinet carries a full high-density GPU row.
  • Dual pumps, dual feeds, variable-speed control.
  • A plate heat exchanger separates the facility water from the IT secondary loop, so the coolant that reaches the cold plates never mixes with the building circuit. Pump speed follows IT load rather than running at a fixed duty point, which holds the supply temperature steady while GPU power swings between idle and training peaks.
  • Control covers the failure modes that matter in an unmanned hall: dew point monitoring with anti-condensation protection, leak detection, undervoltage supervision, heat-exchanger fouling detection and dual pressure protection with automatic relief. Power-fail memory restores the last setpoints, the unit restarts itself when supply returns, and readings reach the local touch panel, the web portal and the mobile app.
  • The cabinet is specified for NVIDIA GB200/GB300, B200/B300 and H100/H200 racks, Intel Xeon 6 and AMD EPYC 9005 servers. Loop temperatures, flow rates, coolant mix and piping interfaces are set per project, so the same platform fits a new AI hall and a retrofit of an air-cooled room without a plant room or ducting.

Frequently Asked Questions

What is the cooling capacity of 600 kW GPU Cabinet CDU for GB200 / GB300?

600 kW per unit

What power supply does the 600 kW GPU Cabinet CDU for GB200 / GB300 use?

Dual feed, three-phase, voltage set per project

What leak detection does the 600 kW GPU Cabinet CDU for GB200 / GB300 use?

Continuous cabinet monitoring

What power monitoring does the 600 kW GPU Cabinet CDU for GB200 / GB300 use?

Undervoltage supervision, power-fail memory, auto restart

Related Products

← Back to Products