8-Outlet GB Switched Rack PDU, 1U Horizontal, 63 A
Switched PDU

8-Outlet GB Switched Rack PDU, 1U Horizontal, 63 A

Quick Answer8-Outlet GB Switched Rack PDU, 1U Horizontal, 63 A — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  4. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  5. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  6. Runs below zero — Tested from sub-zero ambient upward, so cold shelters and unheated halls are inside the envelope, not outside it.
  7. Built to drawing, not to a catalogue — Outlet mix, cable length and plug are set per order — sample-grade customisation without a tooling charge.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Eight Chinese GB outlets with anti-drop latches, 1U horizontal
  • Per-outlet switching and metering on a 63 A single-phase feed
  • Built for edge cabinets, wall boxes and small branch racks
  • Small cabinets usually hold one switch, one server, a firewall and a few appliances, and every one of them comes with a GB three-pin plug. This 1U strip gives eight such outlets, each with an anti-drop latch so a cord cannot walk out of the socket under vibration or when a cable is pulled. Outlets switch and meter individually, which lets an operator reboot a single firewall from a central console while the rest of the branch cabinet keeps running.

Frequently Asked Questions

Eight outlets on a 63 A inlet seems mismatched — why that combination?

The inlet is sized for the branch feed, not for eight times 10 A. In an edge cabinet the strip is usually fed from a 63 A sub-feed shared with other equipment, and the spare capacity lets the same strip be reused when the cabinet grows. Each outlet still protects at its own 10 A rating.

What does the anti-drop latch actually hold?

A spring clip in the socket body grips the plug's earth pin shank, so the plug needs a deliberate pull to release. In cabinets that see vibration from fans or nearby machinery, this stops intermittent drops that look like random reboots.

Can a single firewall be rebooted without dropping the switch?

Yes. Outlets switch individually. When you cycle the firewall outlet, the switch, server and other outlets keep their power and their metering records.

Why 1U horizontal instead of a vertical strip in a small cabinet?

Small wall cabinets often have no usable vertical rail space, and a 1U strip fits above or below the patch panel. The 467 mm body leaves room at the side for cable entry.

Does the strip report energy per outlet or only in total?

The LCD shows total current, voltage, power and energy; per-outlet current and energy are available through the web interface, SNMP and Modbus TCP, so a tenant can be billed from the same data.

Can we order a different outlet type for export?

Yes. GB, Schuko, NEMA, BS 1363, SANS 164 and IEC positions can be combined to drawing, with cord length and plug type to match. Drawings in 30 minutes, quotation in one hour.