Home / Products / Horizontal Breaker Rack PDU, 19-inch, 110–250 V, Black
Horizontal Breaker Rack PDU, 19-inch, 110–250 V, Black
DC distribution panel

Horizontal Breaker Rack PDU, 19-inch, 110–250 V, Black

Quick AnswerHorizontal Breaker Rack PDU, 19-inch, ⁦110–250⁩ V, Black — an IDCPDU DC distribution panel for data-centre and equipment-room racks.
  1. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  2. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  3. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  4. Runs below zero — Tested from sub-zero ambient upward, so cold shelters and unheated halls are inside the envelope, not outside it.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Compact horizontal chassis with breaker
  • 94.7 mm body for shallow cabinets
  • Socket mix built to your drawing
  • The shallowest chassis in the family: at 94.7 × 132 mm it fits 350 mm deep wall cabinets where a full-depth PDU will not close.
  • Input arrives on a copper bar through an integrated breaker; the black powder coat matches standard 19-inch racks and hides handling marks on site.
  • Used in network closets, CCTV enclosures, kiosk cabinets and OEM builds with a fixed shallow footprint.
  • Send the outlet list for a layout drawing within 30 minutes and a quotation within 1 hour.

Frequently Asked Questions

Will it fit a 350 mm deep wall cabinet?

Yes — the 94.7 mm body leaves room for the door and rear cable bend, which is the reason this chassis exists.

How many outlets fit?

Typically ⁦6–10⁩ national sockets or ⁦8–12⁩ C13 modules; the exact count is fixed in the layout drawing.

Can it be fitted with a C20 inlet instead of hard wiring?

Yes, a C20 or national plug inlet can replace the terminal block on request.

Is the breaker accessible from the front?

Yes, the breaker sits on the front face so it can be used as a local isolator without removing the unit.

Does the black finish scratch easily?

It is a powder coat over cold-rolled steel, the same finish used on our rack PDUs; touch-up paint is supplied on request.

What is the lead time?

Layout within 30 minutes, quotation within 1 hour, production ⁦7–15⁩ working days after approval.