K5 19-Inch Server Cabinet (42U–47U)
Server Rack Cabinet

K5 19-Inch Server Cabinet (42U–47U)

Quick AnswerK5 19-Inch Server Cabinet (42U–47U) — an IDCPDU Server Rack Cabinet for server rooms and equipment rooms.
  1. 2,000 kg static load — Rated for fully populated GPU racks, not just the 600 kg that office-grade cabinets quietly assume.
  2. 2.0 mm mounting rails — Rails and side beams are specified by thickness, so a loaded rack does not sag and the doors still close after years of service.
  3. Height, width and depth from one coded matrix — Sizes are ordered by model code, so a project mixing heights still ships as one order and one spare-parts family.
  4. IP2X finger-safe internals — Front and rear doors interlock with the frame so a technician cannot reach live parts during routine patching.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Patented profile frame carrying a 2,000 kg static load
  • Flat-pack shipment for smaller volume and lower freight cost
  • Single-leaf mesh front door and double-leaf mesh rear door
  • The frame ships knocked down with welded frame rings, top and bottom panels, side beams and mounting rails, so one pallet carries more cabinets and freight cost drops.
  • Assembly is quick and needs no welding, and the recessed side panels let cabinets be bayed together with the panels left in place.
  • Graduated mounting rails, close-pitch modular holes and closable cable entries at several points make device location, earthing and cable routing straightforward.
  • A front-to-rear separation inside the cabinet stops cold and hot air from mixing, and the accessory range covers power distribution, cabling and sealing.
  • Compliant with ANSI/EIA RS-310-D, IEC ⁦60297-2,⁩ DIN 41494 Part 1 and Part 7 and GB/T ⁦19520.16-2015,⁩ and compatible with ETSI.

Frequently Asked Questions

What does flat-pack delivery mean for the K5?

The frame, top and bottom panels, side beams, rails and doors ship as separate parts, so one pallet carries more cabinets and freight cost drops.

What load does the K5 cabinet carry?

2,000 kg static load with support brackets, matching the heaviest models in the range.

Does on-site assembly need welding?

No. The patented profile frame with welded frame rings bolts together on site, without welding equipment.

Can cabinets be bayed with the side panels fitted?

Yes. The recessed side panels allow bay-to-bay connection with the panels left in place.

What is the door airflow rate?

Single-leaf mesh front door and double-leaf mesh rear door, both above 75% open area.

Which sizes are available?

42U (2000 mm) and 47U (2200 mm) heights, 600 and 800 mm widths, and 1000, 1100 or 1200 mm depths across 12 standard models.