| Rack standard | 19-inch EIA-310 |
| Installation | Vertical (0U) |
| Height | 2.5U body section (111 mm) |
| Mounting length | 1300 mm |
| Outlet configuration | 12× IEC C13 + 4× IEC C19, lockable |
| Outlet rating | C13: 10 A; C19: 16 A |
| Input connection | Hard-wired terminal block, 5-wire |
| Input voltage | 220–250 V AC, 50/60 Hz |
| Max input current | 16 A (32 A version to order) |
| Rated power | 3.5 kW at 16 A; 7.0 kW at 32 A |
| Phase | Single-phase |
| Main breaker | 1-pole hydraulic-magnetic breaker, 32 A |
| Surge protection | 1-lamp SPD |
| Metering | LCD, current / voltage / power / energy |
| Monitoring interface | TCP/IP + RS485 Modbus-RTU |
| Outlet switching | None (metered only) |
| Cable entry | Top or bottom |
| Housing | Cold-rolled steel, black powder coat |
| Operating temperature | 10–45 °C |
| Relative humidity | 0–90% RH, non-condensing |
| Included accessories | M6×16 screws, user manual |
| Certification | CE / EMC / RoHS; built under ISO 9001 |
| Customisation | Outlet count, cord length and plug type to drawing |
| Lead time | 7–15 working days after drawing approval |
Datasheet, manual and drawings for this product (PDF).
Our engineers reply within 24 hours on business days.
Tel: +86-574-63783045
Email: ricky@idcpdu.com
Tell us your requirements — our sales team will get back to you with a quotation.
Because cords come out. A machine vibrates, a fan blows hot air along the strip, and a standard C13 works loose until the machine drops offline for a reason nobody can find. A locking module holds the plug mechanically, and the fault that disappears when you touch the cable stops happening.
A damaged module is swapped without removing the strip from the rack and without disturbing the other outlets. Keep one spare module on site and a broken latch costs minutes instead of a strip replacement.
For mixed loads, yes: the ports are not all expected at rating together. If your rack carries high-draw supplies on several ports, order the 32 A version, which raises the inlet and the breaker rather than the outlet count.
Yes. A supply whose current drifts above its neighbours at the same hashrate is visible in the per-port list weeks before it fails, which is the difference between a planned swap and a rack outage.
Vertically on the rear 19-inch rails, 1300 mm between fixing centres, with cable entry at the top or the bottom so the feed can come from a floor box or an overhead tray.
Yes. Outlet count, C13 and C19 ratio, cord length and plug type are built to drawing. Drawings within 30 minutes, quotation within one hour.