| Rack standard | 19-inch EIA-310 |
| Installation | Vertical (0U) |
| Outlet configuration | 20× SA-20 |
| Outlet switching | Per-port remote on/off over TCP/IP |
| Input connection | 5-core cable, OT terminal junction box |
| Input voltage | 415–480 V AC three-phase, 50/60 Hz |
| Rated current | 400 A |
| Max input current | 410 A per phase |
| Max power | 240 kW |
| Phase | Three-phase |
| Main breaker | Moulded-case breaker, 400 A |
| Surge protection | SPD, plus overload and earth-leakage protection |
| Metering | LCD, current / voltage / power / energy per port |
| Monitoring interface | TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485 |
| Housing | Cold-rolled steel, black powder coat |
| Operating temperature | 10–45 °C |
| Relative humidity | 0–90% RH, non-condensing |
| Included accessories | 4× M4×16 screws, user manual |
| Certification | CE / GS / EMC; built under ISO 9001 |
| Customisation | Port count, cable length and socket format to drawing |
| Lead time | 7–15 working days after drawing approval |
Datasheet, manual and drawings for this product (PDF).
Our engineers reply within 24 hours on business days.
Tel: +86-574-63783045
Email: ricky@idcpdu.com
Tell us your requirements — our sales team will get back to you with a quotation.
Cable and space. Six 63 A strips need six feeds, six breakers and six cable runs from the same busbar; one 400 A strip needs one five-core run and one breaker. Fewer joints in a hot hall also means fewer hot spots, which is what actually fails in a mining room.
The limit is the 240 kW, not the port count. At 3.5 kW per machine that is roughly sixty-eight machines across twenty ports, so several machines share one port through a short jumper strip. Port count is chosen by how you want to group machines, not by how many you have.
A restart without walking the aisle. When one machine drops off the pool, the operator cycles that port from the dashboard and watches current come back, instead of pulling a cord in a 45 °C aisle. The other nineteen ports stay live, so hashrate loss is one machine rather than one row.
Five-core cable into OT terminal junction boxes inside the enclosure, with the cable supplied to the site rating. The main moulded-case breaker isolates the whole strip for service, and each port keeps its own breaker downstream.
Surge protection, overload protection and earth-leakage protection in the same enclosure, plus per-port breakers. Sensors for temperature and humidity can be added on the plug-and-play ports, so the strip alarms on rising inlet temperature before machines start throttling.
Yes. Port count, SA-20 socket format, cable length and terminal type are built to drawing. Drawings within 30 minutes, quotation within one hour.