ORV3-RACK-44OU OCP Open Rack V3 Liquid Cooling Ready Rack
Liquid-Cooled Server Cabinets

ORV3-RACK-44OU OCP Open Rack V3 Liquid Cooling Ready Rack

Quick AnswerORV3-RACK-44OU OCP Open Rack V3 Liquid Cooling Ready Rack — an IDCPDU Liquid-Cooled Server Cabinet for liquid-cooled OCP racks.
  1. 48 V DC busbar with hot-swap shelves — Power shelves are replaced live, so a failed rectifier costs a swap, not a rack outage.
  2. DLC-ready space reserved — CDU bay and pipe routing are designed in from the start, so the rack is not re-cut when air cooling runs out.
  3. OCP Open Rack V3, 44OU / 21 inch — Native ORV3 hardware fits without an adapter, which keeps the rack interchangeable across OCP suppliers.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • 21-inch inner width, 44OU of mounting space, 1200 mm depth.
  • 48V DC busbar rated 30 kW, hot-swappable power shelves.
  • Pre-reserved CDU bay and liquid pipeline routing.
  • The unit follows the OCP Open Rack V3 base specification and is OCP certified. ORV3 IT hardware mounts natively, and 19-inch EIA equipment fits through adapter frames, so a mixed fleet runs on the same 21-inch platform.
  • Power comes from a 48V DC busbar rated 30 kW with hot-swappable power shelves. Centralised distribution replaces the dense internal cabling of conventional builds and covers the draw of high-density servers and AI computing equipment.
  • Space for a CDU and liquid pipelines is reserved inside the cabinet, so rack-level direct liquid cooling can be fitted at build time or added later. CDUs and manifolds are selected per project to form a complete cooling loop. Deployments cover AI data centres, GPU clusters, HPC and supercomputing centres, and high-density colocation.

Frequently Asked Questions

What is an OCP ORV3.0 liquid-cooled server rack?

The OCP ORV3.0 liquid-cooled server rack is an open rack design based on the OCP Open Rack V3 standard. It uses a 21-inch architecture and 44OU configuration and is designed for AI servers, GPU clusters and high-density computing applications.

What applications is this server rack suitable for?

This rack is suitable for AI data centers, GPU computing clusters, high-performance computing (HPC) and other high-density computing environments.

Does the rack support liquid cooling systems?

Yes. Depending on project requirements, the rack can be configured with liquid cooling components such as CDUs and manifolds, and can be integrated into a complete liquid cooling system.

What are the advantages of the 48V busbar power system?

The 48V busbar system provides centralized power distribution, helping reduce complex internal cabling and supporting the power requirements of high-density servers and AI computing equipment.

Is the OCP ORV3.0 rack suitable for AI and GPU servers?

Yes. The open rack architecture is designed to support high-density computing environments, including AI servers, GPU clusters and HPC systems. Configurations can be customized according to server specifications and project requirements.

Is customization available?

Yes. The rack can be configured according to customer requirements, including server deployment, power distribution, liquid cooling components and other project-specific configurations.